Chatsworth Data Center Solutions

Whether you are designing a new data center or enhancing an existing one, CPI can help you achieve the ultimate solution based on your specific needs today, while allowing you the flexibility to succeed tomorrow. Our unique combination of exceptional solutions and services will help you achieve all of your data center objectives. CPI's data center solutions provide the following benefits:

  • Keeps equipment cool using CPI Passive Cooling® Solutions
  • Provides quick return on investment/reduces energy consumption
  • Uses space effectively with flexible layout solutions that grow with your needs
  • Delivers, monitors and controls power to equipment
  • Connects equipment with clearly defined and organized cable pathways
  • Protects equipment with intelligent locking systems and complete grounding options
  • Monitors conditions such as environment, safety and security

 

CPI Passive Cooling® Solutions

CPI Passive Cooling® Solutions is the most cost effective and cooling effective thermal management solution on the market. It provides superior equipment cooling performance while reducing your data center cooling energy costs. By offering innovative airflow management techniques, CPI Passive Cooling Solutions allow you to maximize your cooling efficiencies without the need for additional CRAC units, in-row air conditioners or risky liquid cooling solutions. From small applications with heat loads of 2 kW per cabinet to large data center applications with heat densities up to 30 kW, CPI Passive Cooling Solutions provide advanced thermal management with zero points of failure, thus delivering a Tier IV solution.

  • Lowers construction costs relative to active cooling solutions
  • Reduces data center cooling costs up to 90%, and saves up to 40% on total data center energy costs
  • Reduces energy consumption by providing 100% HVAC utilization of cool supply air 
  • Allows for higher Delta T’s between the data center cooling air and exhaust air
  • Allows for raised thermostat setting, lowering energy consumption and costs
  • Allows for Tier IV operation because there are no moving parts that require redundant systems
  • Blocks by-pass airflow around equipment, reducing wasted cooling capacity
  • Eliminates dependence on close proximity of perforated floor tiles to cabinets by creating a consistent air temperature throughout the room
  • Permits chilled water temperatures to be increased, providing means for more economizer days while using the same space

 

Live Video Demonstrates How to Manage
High Heat Loads in Your Data Center